dc.description |
This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique. |
|
dc.publisher |
The Brazilian Society of Mechanical Sciences |
|
dc.source |
Journal of the Brazilian Society of Mechanical Sciences |
|
dc.subject |
Multiphase Flow |
|
dc.subject |
Measurements |
|
dc.subject |
Tomography |
|
dc.title |
A high frequency electronic transducer for multiphase flow measurements |
|