DSpace Repository

Estudio de la corrosión del cobre por vapores de ácido acético al 40 y 80 % de humedad relativa

Show simple item record

dc.creator Cano Díaz, Emilio
dc.creator Simancas Peco, Joaquín
dc.creator Narváez, L.
dc.creator Bastidas Rull, José María
dc.date 2008-05-23T07:59:36Z
dc.date 2008-05-23T07:59:36Z
dc.date 2004-03
dc.date.accessioned 2017-01-31T01:26:42Z
dc.date.available 2017-01-31T01:26:42Z
dc.identifier Boletín de la Sociedad Española de Cerámica y Vidrio 43(2): 212-215 (2004)
dc.identifier 0366-3175
dc.identifier http://hdl.handle.net/10261/4474
dc.identifier.uri http://dspace.mediu.edu.my:8181/xmlui/handle/10261/4474
dc.description [ES] En la actualidad hay un gran interés por estudiar la corrosión ocasionada por contaminantes existentes en atmósferas interiores, fundamentalmente ácidos orgánicos. De entre ellos, el más importante es el ácido acético. En este trabajo se ha estudiado la corrosión del cobre por exposición a vapores de ácido acético, a tres concentraciones (10, 100 y 300 ppm), a humedades relativas (HR) del 40 y 80 % y con un tiempo de exposición de 21 días. La velocidad de corrosión se ha cuantificado por métodos gravimétricos, obteniendo velocidades de corrosión de entre 0,08 y 0,17 mg/(dm2·día) (mdd) para el 40 % HR, y entre 0,11 y 6,53 mdd para el 80 % HR. Los productos de corrosión se han caracterizado por espectroscopía fotoelectrónica de rayos X (XPS) combinada con decapado por iones Argón. Los principales productos de corrosión encontrados fueron cuprita [Cu2O], hidróxido de cobre [Cu(OH)2] y acetato de cobre [Cu(CH3COO)2].
dc.description [EN] Recently, there has been an increasing interest in the study of corrosion originated by pollutants in indoor environments, mainly organic acids. Amongst them, the most important is acetic acid. Copper corrosion originated by acetic acid vapours has been studied in this work, at three vapour concentrations (10, 100, and 300 ppm), at 40% and 80% relative humidity (RH) for a period of 21 days. Corrosion rate, obtained using gravimetric methods, was in the range from 0.08 to 0.17 mg/(dm2·day) (mdd) for 40% RH and from 0.11 to 6.53 mdd for 80% RH. Corrosion products have been studied using X-ray photoelectron spectroscopy (XPS), and argon-ion sputtering techniques. The main compounds found were cuprite [Cu2O], copper hydroxide [Cu(OH)2] and copper acetate [Cu(CH3COO)2].
dc.description Peer reviewed
dc.format 537135 bytes
dc.format application/pdf
dc.language spa
dc.publisher Sociedad Española de Cerámica y Vidrio
dc.relation http://boletines.secv.es/es/index.php?id=18&vol=43
dc.rights openAccess
dc.subject Corrosion en interiores
dc.subject Cobre
dc.subject Ácidos orgánicos
dc.subject Ácido acético
dc.subject Indoor corrosion
dc.subject Copper
dc.subject Organic acids
dc.subject Acetic acid
dc.title Estudio de la corrosión del cobre por vapores de ácido acético al 40 y 80 % de humedad relativa
dc.title Study of copper corrosion by acetic acid vapours at 40 and 80% relative humidities
dc.type Artículo