DSpace Repository

Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa.

Show simple item record

dc.contributor Médecins sans Frontiérès, Medical Department, Brussels Operational Center, Brussels, Belgium.
dc.creator Chaillet, Pascale
dc.creator Tayler-Smith, Katie
dc.creator Zachariah, Rony
dc.creator Duclos, Nanfack
dc.creator Moctar, Diallo
dc.creator Beelaert, Greet
dc.creator Fransen, Katrien
dc.date 2010-09
dc.date.accessioned 2017-01-31T07:20:12Z
dc.date.available 2017-01-31T07:20:12Z
dc.identifier Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa. 2010, 104 (9):571-6 Trans. R. Soc. Trop. Med. Hyg.
dc.identifier 1878-3503
dc.identifier 20708123
dc.identifier 10.1016/j.trstmh.2010.05.007
dc.identifier http://hdl.handle.net/10144/112714
dc.identifier http://fieldresearch.msf.org/msf/handle/10144/112714
dc.identifier Transactions of the Royal Society of Tropical Medicine and Hygiene
dc.identifier.uri http://dspace.mediu.edu.my:8181/xmlui/handle/10144/112714
dc.description With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tests (INNO-LIA HIV-I/II Score) and NEW LAV BLOT II (Bio-Rad). Four hundred and forty three sequential stored HIV-positive serum samples, of known HIV-type, were evaluated. Genie II HIV1/HIV2, Immunoflow HIV1-HIV2 and SD Bioline HIV 1/2 3.0 had 100% sensitivity (95% CI, 98.9-100%) while for First Response HIV Card Test 1-2.0 this was 99.5% (95% CI, 98.2%-99.9%). In terms of discriminatory capacity, Genie II HIV1/HIV2 identified 382/ 384(99.5%) HIV-1 samples, 49/ 52(95%) HIV-2 and 7/7(100%) HIV-positive untypable samples. Immunoflow HIV1-HIV2 identified 99% HIV-1, 67% HIV-2 and all HIV-positive untypable samples. First Response HIV Card Test 1-2.0 identified 94% HIV-1, 64% HIV-2 and 57% HIV-positive untypable samples. SD-Bioline HIV 1/2 3.0 was the worst overall performer identifying 65% HIV-1, 69% HIV-2 and all HIV-positive untypable samples. The use of SD Bioline HIV 1/2 3.0 (the current standard in Guinea-Conakry) as a discriminatory HIV test is poor and may be best replaced by Immunoflow HIV1-HIV2.
dc.language en
dc.rights Published by Elsevier Archived on this site with the kind permission of Elsevier Ltd. ([url]http://www.sciencedirect.com/science/journal/00359203[/url]) and the Royal Society of Tropical Medicine and Hygiene ([url]http://www.rstmh.org/transactions.asp[/url])
dc.title Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa.


Files in this item

Files Size Format View

There are no files associated with this item.